Specification | |
ECG Specification | |
Standard 3-lead or 5-lead | 3-lead RA,LA,LL,Lead method:I,II,III 5-lead RA,LA,LL,RL,V,Lead method:I,II,III,aVR,aVL,aVF,V |
Gain | ×250, ×500, ×1000, ×2000 |
HR Measuring Range | Adult:15 ~ 300bpm (beat/minute) Neonatal baby/children:15 ~ 350 bpm(beat/minute) |
HR Accuracy | ±1% or ±1bpm,the larger prevails |
HR Resolution | 1 bpm(beat/minute) |
Sensitivity | > 200 uV P-P |
Differential Input Impedance | > 5M ohm |
Bandwidth | Diagnostic Mode: 0.05~130 Hz Monitoring Mode: 0.5~40 Hz Operation Mode: 1~20 Hz |
CMRR | Diagnostic Mode: > 90 dB Monitoring Mode: >100 dB Operation Mode: >100 dB |
Electrode Offset Potential | ±300 mV |
Leakage Current | <10 uA |
Pacing Pulse Test | Test pacing pulse in accordance with the following conditions: Range: ±2~±700 mV Width: 0.1~2 ms Rise time: 10~100 us |
Pacing pulse inhibition |
When pacing analysis switch is on, pacing pulse in accordance with the following conditions are restrained, but affection against HR calculation. Range: ±2~±700 mV Width: 0.1~2 ms Rise time: 10~100 us |
Baseline Recovery | < 3s After defibrillation |
Signal Range | ±8mV P-P |
Calibrating Signal | 1mV(Peak-to-peak value),precision:±5% |
ST Segment Measuring Volume | |
Measuring Range: | -2.0mV ~ +2.0mV |
Measuring precision: | Ranging -0.8 mV ~ +0.8mV, measuring error is ±0.02mV or ±10%,The larger prevails. No definition for other ranges. |
Resp Specification | |
Measuring Method | RA-LL impedance |
RESP Impedance Measuring Range | 0.3~3Ω |
Base Impedance Range | 200~4000Ω |
Bandwidth | 0.1~2.5Hz |
RR Measurement Range | Adult: 0~120BrPM Children and neonatal baby: 0~150 BrPM |
RR Resolution | 1 BrPM |
RR Precision | ±2 BrPM |
Asphyxia Alarm | 10~40 seconds |
NIBP Specification | |
Measuring Method | Pulse wave oscillometry |
Work Mode | Manual/Automatic/STAT |
Measuring Interval of Automatic Measuring Mode | 1,2,3,4,5,10,15,30,60,90,120,180,240,480 minute(s) |
Measuring Time of STAT Mode | 5 minutes |
PR range | 40 - 240 bpm |
Measuring Range | Adult Sys: 40~270mmHg Dia: 10~215mmHg Mean: 20~235mmHg Children Sys: 40~200mmHg Dia: 10~150mmHg Mean:20~165mmHg Neonatal baby Sys: 40~135mmHg Dia: 10~100mmHg Mean: 20~110mmHg |
Static Pressure Range | 0~300mmHg |
Static Pressure Precision | ±3mmHg |
Pressure precision | Max. average error: ±5mmHg; Max. standard deviation: 8mmHg |
Over voltage protection |
Adult mode: 300 mmHg Children mode: 240 mmHg Neonatal baby mode: 150 mmHg |
SpO2 Specification | |
SpO2 Measuring Range | 0~100% |
SpO2 Resolution | 1% |
SpO2 Precision | 70~100%: ±2 DIGIT 0%~69%: no definition given |
PR Measuring Range | 20~300bpm |
PR Resolution | 1bpm |
PR Precision | ±3bpm |
Temp Specification | |
Temperature Sensor | YSI series,CYF series |
Channel Quantity | 2 Channels |
Measuring Range | 0~50ºC |
Resolution | 0.1ºC |
Precision | ±0.1ºC(Excluding Sensor Error) |
IBP Specification | |
Label | ART, PA, CVP, RAP, LAP, ICP, P1, P2 |
Measuring and alarm range | ART: 0~300 mmHg PA: -6~120 mmHg CVP/RAP/LAP/ICP: -10~40 mmHg P1/P2: -10~300 mmHg |
Press Sensor Sensitivity | 5 uV/V/mmHg |
Press Sensor Impedance | 300-3000Ω |
Resolution | 1 mmHg |
Accuracy | ±2% or±1mmHg, which great |
Actualization interval | about 1 Sec. |