Dimensions(mm) | 266(L)×141(W)×145(H) |
Weight | 2Kg |
Power supply | AC 100V~AC 242V,50/60HZ(±1 HZ) |
Built-in batteries | DC 12V 1800mAh |
Battery Model | JBT Ni-MH, rechargeable |
Battery Continuous Use Time | At least 4hrs(Fully charged new battery, under 5ml/h running) |
Power consumption | ≤25 VA |
Infusion Flow Selection | 0.1ml/h~1600ml/h, original value is 0.1ml/h |
Bolus rate | Syringe 50ml:1600ml/h |
Syringe 30ml:900 ml/h | |
Syringe 20ml:600 ml/h | |
Syringe 10ml:400 ml/h | |
Infusion Range | 0.1ml~9999.9ml, original value is 0.1ml |
Flow Rate Precision | ±3% |
Occlusion Pressure | High:110kPa±20kPa (825mmHg±150 mmHg) |
Middle:80kPa±30kPa (600mmHg±225mmHg) | |
Low:60kPa±20kPa (450mmHg±150 mmHg) | |
The biggest output pressure | < 975mmHg(130kPa) |
Use Environment | Temperature: 5ºC~43ºC |
Relative Humidity: ≤90%RH (Under without condensation status) | |
Atmospheric Pressure: 860hPa~1060hPa | |
Storage Environment | Temperature: -40ºC~+55ºC |
Relative Humidity: ≤90%RH (Under without condensation status) | |
Atmospheric Pressure: 860hPa~1060hPa | |
Waterproof Level | IPX4 |
Electric Shock Protection | Class I, Type CF |
Alarm | Occlusion, nearly finish, finish, standby (no operation) low battery, battery exhausted etc. |
Function | Transfusion amount display, flow rate display, infused volume display |
KVO (Keep Vein Open) | After finish setting infusion amount, for prevent to form thrombus, keep to infusion at the lowest rate 0.1ml/h. |
Power Switching Function | When AC power is disconnected, automatically switch into battery power supply and give indication. When the AC power is connected, automatically switch into AC power working. |
Repeat Alarm Function | If the alarm real reason is not be resolved within 2 minutes after press "SILENCE" button, it will give alarm again to remind to resolve the problem. |
Data Memory Function | Able to save the latest setting alarm volume level, brand, occlusion pressure. level for use next time. Able to save for five years. |
Battery Protection Alarm | For protect battery and safety infusion, the battery power will be displayed as different levels in sound and light from nearly finish to exhausted |
Move alarm | When try to move or take the syringe away, it will give alarm. |